Options:
-slot
The slot number in the chassis.
-all
All slots in the chassis.
Sample Output:
-> showLastScpRetCode 101
SCP: Slot 101 Last Exit Code: 0: Success
fwVersion
Displays the firmware versions for a unit.
Syntax:
fwVersion [slot]
Options:
slot
Slot number.
Sample Output:
-> fwVersion
Slot 105 Information -----------------
Firmware Version: 4.1.1.1.11
Firmware build:
Firmware BSP:
MBC Version:
Bootrom Version:
Slot 106 Information -----------------
Firmware Version: 4.1.1.1.11
Firmware build:
Firmware BSP:
MBC Version:
Bootrom Version:
bootQuery
Displays boot image version information.
Syntax:
bootQuery slot [-active | -alternate | -all]
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
B-32
NOTES: This allows for automated systems to determine if a SCP firmware push was
successful or not.
4_1_1_1_11
t3