Diagnostic Software, To Read Warning History - Yamaha DPX-530 Service Manual

Digital cinema projector
Hide thumbs Also See for DPX-530:
Table of Contents

Advertisement

DPX-530
DIAGNOSTIC SOFTWARE, TO READ WARNING HISTORY (PCGC8 Ver.2)
*Pcgc8 Ver.2 is upwardly compatible with Pcgc8 Ver.1.
1. Preparation
PCGC8 supports Microsoft
a PC with Windows
®
95/98/Me/XP installed.
1. Copy the folder named "Pcgc8.2 (English)" in the CD-
ROM onto the desktop.
2. Connect the PC with the projector by RS-232C cable
(service component).
3. Click "Pcgc8e.exe" in the folder named "Pcgc8.2 (English)."
2. Operation
(1) Model name selection dialog window
Starting Pcgc8 displays the model name selection dialog
window. Select the model name you want to use and press
the OK button to display the main dialog window. Press the
Cancel button to exit the application.
The list of the available model names is displayed.
Select one model name you want to use.
Select [DPX-530] when
using DPX-530
Goes to the main
dialog window.
Model name selection dialog window
Displays the information about the connected device.
The contents depend on the selected model.
Displays the selected
model name.
Displays the
Warning History 1.
38
®
Windows
®
95/98/Me/XP. Use
DPX-530
Exits this application.
DPX-530
DPX-530
DPX-530
Displays the
Displays the
Warning History 2.
Warning History 3.
Main dialogue window
(2) Main dialog window
1. The main dialog window displays the information stored
in the projector (model name, serial No., software
version, etc.) and the service menu information.
Information displayed in this window depends on the
selected models.
2. Some PCs may not be able to connect to the right COM
port. In such cases, press the Change COM PORT
button to switch the COM port. Refer to (4) Switching
the COM port.
3. Press any of the Warning History 1, Warning History 2,
or Warning History 3 button to display the warning
dialog window containing the detailed error data.
4. Press the DIAGNOSIS button to start self-diagnosis.
(Not available during power on and when an error
occurs.)
Warning History 1: The latest warning history data are stored
in the Warning History 1. The data
remain after the error is corrected.
Warning History 2: The second oldest warning history data
are stored in the Warning History 2.
Warning History 3: The oldest warning history data are
stored in the Warning History 3.
Note: When the power is turned off because of any error,
the warning history data are saved. Or, only when an
error occurs during power on or when an error is
detected during self-diagnosis (or immediately after
pressing the DIAGNOSIS button), the warning history
data are saved. (The warning history data aren't
saved when the stand-by power fails during the
stand-by mode. In this case, LED warning indication
will appear. Check the error data by the warning
status.)
Displays the current date and time
when the error is corrected.
Starts self-diagnosis.
Switches the COM
port.
Exits the application.

Advertisement

Table of Contents
loading

Table of Contents