Service Commands; Life Time Of The Consumable Parts - Yamaha DPX-530 Service Manual

Digital cinema projector
Hide thumbs Also See for DPX-530:
Table of Contents

Advertisement

SERVICE COMMANDS

Display the operation status screen
Hold down the [
], [
], and [ENTER] buttons on the projector together to
display the picture shown on the right.
Press the [MENU] button to cancel this picture.
S/W VERSION
: The software's version
SET TIME
: Projector operating time (Cumulative projector operating
time), impossible to reset.
LAMP TIME
: Lamp operating time, possible to reset.
LAMP RESET
: Number of times the lamp operating time has been reset,
impossible to reset.
V-FREQ
: Vertical frequency of the input signal
H-FREQ
: Horizontal frequency of the input signal
TEMP-ERR OR TIME : Time when a temperature error occurred.
0H0M is displayed when the power hasn't been turned off
because of a temperature error.
(ERR MODE)
: The sensor that caused power-off is indicated within the
parentheses.
(*1)
IN TEMP
: Intake temperature (°C)
(*1)
LAMP TEMP
: Lamp temperature (°C)
*1)
The figures in the parentheses are the "temperature when the
power is turned off due to a temperature failure". The default value 0
is shown in the parentheses when the warning record has been
reset. Table 1 shows the temperature setting for each sensor.
FAN MODE
: Rotation speed of the fan (0 to 25)
Reset to the factory settings
Use the procedure below to reset the setting values and the warning record to
the factory settings.
Press the [MENU], [ENTER], and [
time.
When the reset command is accepted, the STATUS LED will flash green two
times.
Note1: It takes about 10 seconds for the projector to complete the process
of resetting to the factory settings because the iris is fully opened in
the process. Upon completion of the reset process, the STATUS
LED will flash green two times. Do not disconnect the AC cord while
the STATUS LED is flashing.
Note2: After the settings are reset, the menu language will be English.
Reset the lamp operating time
After replacing the lamp, reset the lamp operating time using the procedure
below.
Plug in the power cable and press the [STANDBY/ON], [
on the projector at the same time.
When the reset command is accepted, the STATUS indicator will flash two times.

LIFE TIME OF THE CONSUMABLE PARTS

Following are the reference of the life times of the consumable parts.
• Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max. 4,000 hours (When LAMP MODE is CINEMA.)
• CW UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. 5,000 hours
• Cooling fan (power) . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (DMD) . . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (lamp) . . . . . . . . . . . . . . . . . . . . . . Approx. 10,000 hours
• Cooling fan (exhaust) . . . . . . . . . . . . . . . . . . . Approx. 5,000 hours
] buttons on the projector at the same
] and [
Max. 2,000 hours (When LAMP MODE is BRIGHT.)
(Example)
S/W VERSION
SET TIME
LAMP TIME
LAMP RESET
V-FREQ
H-FREQ
TEMP ERROR TIME
(ERROR MODE)
(ERROR LAMP MODE)
IN-TEMP
LAMP-TEMP
FAN MODE
SENSOR
indication at
IN TEMP
LAMP TEMP
Table 1 TEMPERATURE SETTING FOR EACH SENSOR
] buttons
DPX-530
1.00DP53
519H 04M
519H 04M
1
60 Hz
48.4 kHz
1000H 20M
(INTAKE)
(STANDARD)
25.0
(48.0 ˚C)
44.0
(78.0 ˚C)
0
(25)
MENU
Finish
Warning
Forced
Power-on
power-off at
at
51 °C
52 °C
47 °C
84 °C
85 °C
75 °C
25

Advertisement