Functional safety

Drive unit specifications
Item
Safety
Satisfied standards
performance
Mean time to dangerous failure
(MTTFd)
Diagnostic coverage (DC)
Probability of dangerous Failure per
Hour (PFH)
Mission time (T
*1 When DI/O connection (CN8) is used, diagnosis by test pulses is required in order to satisfy Category 4 PL e, SIL 3.
*2 Although the special proof tests within the mission time of the safety sub-function is not needed to be performed, the suggested
diagnostic test interval in IEC 61800-5-2: 2016 is at least one test per three months for Category 3 PL e, SIL 3.
Function specifications
Item
Safety sub-function
STO
*1*2
SS1
SBC
I/O function
Input device
Output device
*1 Available functions and safety levels differ depending on the combination of the drive units and the servo motors.
Page 17 List of safety sub-function compatible units
*2 When DI/O connection (CN8) is used, diagnosis by test pulses is required in order to satisfy Category 4 PL e, SIL 3.
*3 A test pulse is a signal which instantaneously turns off a signal to the drive unit at a constant period for external circuits to perform self-
diagnosis.
1 SPECIFICATIONS
16
1.4 Drive unit standard specifications
Specifications
*1
EN ISO 13849-1:2015 Category 4 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2
MTTFd ≥ 100 [years] (750a)
DC = Medium, 96.5 [%]
PFH = 3 × 10
*2
)
T
= 20 [year]
M
M
Shut-off response time (STO input off →
energy shut off)
Deceleration delay time
Shut-off response time
Number of inputs
Permissible time for mismatched double
inputs
Noise elimination filter
*3
Test pulse off time
Number of outputs
*3
Test pulse off time
*3
Test pulse interval
-9
[1/h]
Specifications
8 ms or less (when an input device is used)
0 ms to 60000 ms (set by functional safety parameters)
8 ms or less (when an input device is used)
1 point × 2 systems
0 ms to 60000 ms (set by functional safety parameters)
1.000 ms to 32.000 ms (set by functional safety parameters)
1 Hz to 25 Hz
1 point × 2 systems
0.500 ms to 2.000 ms (set by functional safety parameters)
Within 1 s