You Can't Start the Setup Program
This may be due to the copy of the PC's configuration in memory being corrupted by a
program. You will need to erase this bad configuration.
1. Switch off the PC and remove the cover (see "Removing and Replacing the Cover").
2. Move the system board jumper JP5 to position 2-3 (see "System Board Connectors and
Jumpers").
3. Switch on the PC to erase the memory.
4. Switch on the PC and check that the message Configuration has been cleared
(in English) is displayed, and allow the PC to complete it's startup routine.
5. Switch off the PC.
6. Return the system board jumper JP 5 to position 1-2.
7. Replace the cover (see "Removing and Replacing the Cover").
8. Switch on the PC and check that the error codes 0241, 0280, and 0130 are displayed,
indicating that the memory has been successfully cleared.
9. Run the Setup program by pressing [F2] when <Setup=F2 > appears to enter any
configuration changes that have been lost.
10. Press [F3] to save the configuration and exit from the Setup program.
Vectra VE 4/xx User's Guide 4 Troubleshooting