Installation Planning
10.4
Process code
Feeding speed
Processing time in DEV
Processing time
(film 35 x 35 cm)
Film: end / end
incl. Film
Films / h (35 x 35 cm)
Machine tank volumes
Developer
Fixer 1
Fixer 2
Water
Developer tank temperature
standard
adjustable between
25 °C (77 °F) - 39 °C (102.2 °F)
Fixer 2 tank temperature
Heating time from
20 °C (68 °F) to
34 °C (93.2 °F)
Dryer step setting
Standard setting
replenishment cycles
Developer / fixer
Standard setting
Replenishment rate
Developer / fixer
Water
Range
Replenishment rate
Developer / fixer
Water
Water supply
Adjustment range
for water pressure
min.
max.
Water conductivity value
Water pH value
Silver concentration in the
waste water
Chapter 14 / 36

Functional data

HT (60s)
160 cm/min
(62.99 in/min)
12.5 sec
71 sec
82 sec
220
8.8 l (297.6 fl.oz.)
10 l (338.18 fl.oz.)
5.8 l (196.15 fl.oz.)
5.8 l (196.15 fl.oz.)
38 °C
(100.4 °F)
34 °C (93.2 °F)
approx. 20 min
13 (Software Version CLLC1107;
0.25 m² (3.88 in²)
400 ml/m²
30000 ml/m²
50 – 800 ml/m²
3000 – 30000 ml/m²
3000 ml/min (101.45 fl.oz./min)
2 bar
6 bar
min. 3 µS / cm
If the value drops below this threshold reliable level detection
in the water tank can no longer be guaranteed!
6.5 to 8
< 1 ppm
Classic E.O.S. / Classic E.O.S. CL
(Type 5270 / 100 / 105)
IP (90s)
106 cm/min
(41.73 in/min)
18.8 sec
107 sec
124 sec
150
36 °C
(96.8 °F)
older versions: 10 steps)
DD+DIS303.03E
RP (2min)
EXT (3min)
80 cm/min
52 cm/min
(31.5 in/min)
(20.47 in/min)
24.9 sec
38.3 sec
142 sec
218 sec
164 sec
253 sec
110
75
34 °C
34 °C
(93.2 °F)
(93.2 °F)