Panasonic KX-FM330GR Service Manual page 171

Multi-function plain paper fax
Table of Contents

Advertisement

HOW TO REMOVE THE LOWER CABINET AND FILM END SENSOR BOARD
Ref. No. 7
Procedure
5 6 7
1) Remove the 4 screws A .
2) Remove the lower cabinet.
3) Remove the 1 screw B .
3) Remove the film end sensor board.
NOTE:
When you close a lower
cabinet, insert back side first
then set front side.
2
HOW TO REMOVE THE CCD UNIT AND PAPER FULL SENSOR BOARD
Ref. No. 8
Procedure
1 5 6 7 8
(CCD UNIT)
1) Remove the 2 screws A .
2) Remove the cover.
3) Remove the 2 screws B .
4) Remove the CCD UNIT.
PAPER FULL
SENSOR BOARD
HOW TO CLEAN:
Clean the target glass of
CCD unit with soaking cloth
in alcohol.
A
1
A
COVER
CONNECTOR
C
B
C
C
129
A
LOWER CABINET
A
(PAPER FULL SENSOR BOARD)
1) Pull out the 5 connectors.
2) Remove the 3 screws C .
3) Remove the paper full sensor board.
A
B
CCD UNIT
KX-FP320G / KX-FM330G
A
B
FILM END SENSOR BOARD

Advertisement