3.3.

CCD ADJUSTMENTS

To obtain good print quality, perform the following adjustments after replacing the lens and/or CCD board.
3.3.1.
PREPARATION
1. Remove the CCD unit from set. (Refer to 4. DISASSEMBLY INSTRUCTIONS)
2. Make oscilloscope connections as shown in LENS AND CCD READ POSITION ADJUSTMENT.
3. Attach the CCD TOOL on the CCD unit.
4. Connect between CCD unit and digital board with extension cord (Part No. PQZZ8K18Z).
5. Connect between LED array and digital board with extension cord (Part No. PQZZ2K12Z).
6. Connect AC cord.
7. Press the MENU button.
8. Press the #,9,0,0,0, and
9. Press the 5,5 and 5 buttons.
Note:
1. Install the lens so that the marking (RED) is on its upper side.
2. Do not touch the glass face of the lens with bare hands.
3. If you have no instrument to repair the unit, trim off the chart on for LENS AND CCD READ POSITION ADJUSTMENT, then
attach on the target glass (This is a temporary treatment. You should use CCD Tool for this time adjustment for proper
repair.)
Cleaning
If the lens is dirty, clean it with a soft dry cloth.
Note:
Please adjust with covering topside of the lens by hands in order not to let in outdoor daylight.