Omron E3NX-FA Operation Manual page 157

Ethercat digital sensor communication unit
Table of Contents

Advertisement

A-2-2
Mounting and Removing Distributed Sensor Units
This section describes how to mount and remove the E3NW-DS and individual Amplifiers to the DIN
Track.
Refer to "7-3 Mounting Dimensions" on page 7-9 for dimensions of each Distributed Sensor Units.
Mounting Method
Use the following procedure to mount the Units.
1
Hook the upper portion of the Unit on the DIN Track.
2
Press the lower portion of the Unit against the DIN Track.
3
Remove the protective cap from the right side of the Distributed Sensor Unit. Then, slide
the Sensor Amplifier Units against the Distributed Sensor Unit with the tabs aligned with
the notches in the connector area. Press them together until they click into place.
4
Use the DIN Track End Plates (PFP-M) that are provided to remove any gaps between the
Units and secure them in place. Replace the protective cap that you removed in step 3 to
the Sensor Amplifier on the right end.
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
Protective cap
DIN Track
End Plates
A Appendices
Push into place.
A
A - 53