A Appendices
403B + (N-1) × 80
No_01 ... 30 Power Tuning Setting, Tolerance Setting High*, and Scaling Setting Low *2
hex
Subindex 0: Number of Entries
Range: 02 hex
Size: 1 byte (U8)
Subindex 1: No_01 ... 30 Power Tuning Setting IN1, Tolerance Setting High*, and Scaling Setting Low *2
Range*: −1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F hex)
Size: 4 bytes (INT32)
Subindex 2*: No_01 ... 30 Power Tuning Setting IN2
Range*: −1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F
hex)
Size: 4 bytes (INT32)
• This object sets the power tuning setting and tolerance setting high setting of the Sensor with the unit
number that is specified by the index.
• The setting range for the tolerance setting high setting is −1,999,999 to 9,999,999 (FFE17B81 hex to
0098967F hex).
*1 Items with asterisks are supported from E3NW-ECT version 1.03.
*2 Items with asterisks are supported from E3NW-ECT version 1.08.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
Power Tuning Setting data
Data
00000000 hex
00000001 hex
00000002 to FFFFFFFF hex
403C + (N-1) × 80
No_01 ... 0 Power Tuning Level and Tolerance Setting Low*, and Scaling Setting High *2
hex
Subindex 0: Number of Entries
Range: 02 hex
Size: 1 byte (U8)
Subindex 1: No_01 ... 30 Power Tuning Setting IN1 and Tolerance Setting High*, and Scaling Setting High *2
Range*: −1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F hex)
Size: 4 bytes (INT32)
Subindex 2*: No_01 ... 30 Power Tuning Level IN2
Range*: −1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F
hex)
Size: 4 bytes (INT32)
• This object sets the power tuning level and tolerance setting low setting of the Sensor with the unit
number that is specified by the index.
• The setting range is for the power tuning level is 100 to 9999 (00000064 hex to 0000270F hex).
• The setting range for the tolerance setting low setting is −1,999,999 to 9,999,999 (FFE17B81 hex to
0098967F hex).
*1 Items with asterisks are supported from E3NW-ECT version 1.03.
*2 Items with asterisks are supported from E3NW-ECT version 1.08.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
A - 42
Unit: ---
Default: 02 hex
Access: RO
Unit: ---
Defaults: --- hex
Access: RW
Unit: ---
Default: --- hex
Access: RW
Setting
Power Tuning Setting ON
Power Tuning Setting OFF
Not used.
Unit: ---
Default: 02 hex
Access: RO
Unit: ---
Defaults: --- hex
Access: RW
Unit: ---
Default: --- hex
Access: RW
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
Attribute: ---
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: ---
PDO map: Not possible
Attribute: A
PDO map: Not possible
Attribute: A
PDO map: Not possible