Cabling Ethernet Interfaces; Cabling The System For Power - Juniper C Series Hardware Manual

Hide thumbs Also See for C Series:
Table of Contents

Advertisement

C2000 and C4000 Hardware Guide
See "Setting the Initial Configuration" on page 21 for more information about
management access.
Connecting to the Network
To connect the system to the network:
1.
2.
Connecting to a Console Terminal
When you connect a console directly to the system, use a cable appropriate for your
terminal connector. The cable must have a female DB-9 connector to attach to the
RS-232 port on the system.
To connect the console:
1.
2.

Cabling Ethernet Interfaces

Port ETH0 and ETH1 on the C2000 model and the C4000 model accept RJ-45
10/100/1000Base-T Ethernet (copper) interfaces. Port ETH2 and port ETH3 on the
C2000 model and the C4000 model accept SFPs.

Cabling the System for Power

After you have correctly cabled the system, you can then attach the power cord. See
Figure 8 on page 17 and Figure 10 on page 17. See "System Specifications" on page
39 for the power requirements for the system.
To cable the system for power:
1.
2.
NOTE: We suggest that you use an uninterruptible power supply (UPS) with your C
Series Controller.
NOTE: To provide redundancy, do not terminate Power A and Power B leads at the
same power source.
16
Cabling the System
Insert an Ethernet cable (RJ-45) connector into the 10/100Base-T (RJ-45) port on
the system until it clicks into place.
Connect the other end of the cable to the appropriate Ethernet network for an
out-of-band connection.
Insert the female DB-9 connector into the RS-232 port, and tighten the screws.
Connect the other end of the cable to your terminal's serial port (VT100/ANSI).
Insert the power cord into the AC power IEC receptacle.
Insert the other end of the power cord into an appropriate AC power source.