Kyocera Mita KM-2560 Service Manual page 86

Hide thumbs Also See for Mita KM-2560:
Table of Contents

Advertisement

2H0/2HZ
Maintenance
item No.
Setting the KMAS host monitoring system
U202
Description
Initializes or operates the KMAS host monitoring system.
This is an optional device which is currently supported only by Japanese specification machines, so no setting
is necessary.
Checking DP operation
U203
Description
Simulates the original conveying operation separately in the optional DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP if running this simulation with paper.
3. Select the item to be operated.
4. When selecting [ADP] or [RADP], to set the magnification using the +/- keys.
Display
ADP
RADP
ADP (NON P)
RADP (NON P)
SPEED
5. Press the start key. The operation starts.
6. To stop continuous operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-50
Description
Operation
With paper, single-sided original
With paper, double-sided original
Without paper, single-sided original
(continuous operation)
Without paper, double-sided original
(continuous operation)
Switching between normal reading
(600 dpi) and high-speed reading
Setting range
Initial setting
100 to 200 (%)
100
100 to 200 (%)
100
-
-
-
-
0 (Normal)/
0
1 (high-speed)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mita km-30601102h03nl0

Table of Contents