Advertisement

2H0/2HZ
Maintenance
item No.
Adjusting the scanner leading edge registration
U066
Description
Adjusts the scanner leading edge registration of the original scanning.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and original.
Adjustment
1. Press the start key.
2. Select the item to be adjusted.
Display
ADJUST DATA 1
ADJUST DATA2
3. Press the system menu key.
4. Place an original and press the start key to make a test copy.
5. Press the system menu key.
6. Change the setting value using the +/- or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U066
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-28
Description
Description
Scanner leading edge registration
Scanner leading edge registration
(rotate copying)
Scanner leading edge registration
Original
Figure 1-3-11
U403
U071
(P.1-3-65)
(P.1-3-32)
Setting
Initial
range
setting
-45 to 45
0
-45 to 45
0
Copy
Copy
example 1
example 2
U404
(P.1-3-66)
Change in
value per step
0.086 mm
0.086 mm

Hide quick links: