2H0/2HZ
5. Remove the stop ring from the forwarding
pulley retainer.
6. Pull the paper forwarding pulley shaft and
remove the forwarding pulley.
Removing the paper feed pulley
7. Remove two stop rings from the primary
paper feed unit.
8. Pull the paper feed pulley shaft in the direc-
tion of the arrow and remove the paper feed
pulley.
Removing the separation pulley
9. Remove the stop ring from the primary
paper feed unit.
10. Pull the separation pulley shaft in the direc-
tion of the arrow and remove the separation
pulley.