Replacing The Gpu Or Lc Kit - Fujitsu PRIMERGY GX2570 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Liquid cooling (LC)
Concluding steps
"Installing the cross bar" on page
"Installing the air duct" on page
"Installing the CPU node" on page
"Connecting the power cord" on page
"Switching on the server" on page
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
● Restart your server.
● As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
● If a password is assigned, enter the password and press [Enter].
● Select the Exit menu.
● Select Commit settings and Exit.
● Verify that the Global Error indicator stops flashing.
13.3

Replacing the GPU or LC kit

Field Replaceable Unit
(FRU)
– Phillips PH2 / (+) No. 2 screw driver (for GPU node)
Tools:
– Torx T15 screw driver
206
65.
63.
50.
48.
49.
Upgrade and Maintenance Manual
Hardware: 30 minutes
GX2570 M6