Error Codes
Code
timeout in V.34 phase 3 – equalizer
training.
0-82
The line was disconnected due to a
timeout in the V.34 phase 4 – control
channel start-up.
0-83
The line was disconnected due to a
timeout in the V.34 control channel
restart sequence.
0-84
The line was disconnected due to
abnormal signaling in V.34 phase 4 –
control channel start-up.
0-85
The line was disconnected due to
abnormal signaling in V.34 control
channel restart.
0-86
The line was disconnected because
the other terminal requested a data
rate using MPh that was not available
in the currently selected symbol rate.
0-87
The control channel started after an
unsuccessful primary channel.
0-88
The line was disconnected because
PPR was transmitted/received 9
(default) times within the same ECM
frame.
2-11
Only one V.21 connection flag was
received
2-12
Modem clock irregularity
2-13
Modem initialization error
SM
Meaning
Suggested Cause/Action
If these errors happen at the transmitting terminal:
•
Try making a call at a later time.
•
Try using V.17 or a slower modem using
dedicated TX parameters.
•
Try increasing the TX level.
•
Try adjusting the TX cable equalizer setting.
If these errors happen at the receiving terminal:
•
Try adjusting the RX cable equalizer setting.
•
Try increasing the TX level.
•
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
•
The signal did not stop within 10 s.
•
Turn off the machine, then turn it back on.
•
If the same error is frequent, replace the FCU
(PCB2).
•
The signal did not stop within 10 s.
•
Turn off the machine, then turn it back on.
•
If the same error is frequent, replace the FCU
(PCB2).
•
The other terminal was incompatible.
•
Ask the other party to contact the manufacturer.
•
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
•
This does not result in an error communication.
•
Try using a lower data rate at the start.
•
Try adjusting the cable equalizer setting.
•
Replace the FCU (PCB2).
•
Replace the FCU (PCB2).
•
Turn off the machine, then turn it back on.
•
Update the modem ROM.
25