Code
Message Displayed
E261
Fr Cal illumination failure
E262
Rr Cal illumination failure
E263
Calibration target too short
E264
Cal target front too dark
E265
Cal target rear too dark
E278
Re-scan - doc feed error
E291
Scanner disabled
E294
Fr Cal Fail - calibration reqrd
E295
Rr Cal Fail - calibration reqrd
6-8
Description/Action Required
A front lamp failure was detected during calibration.
Press Jog to remove the calibration target. Press
Cal and try to calibrate the scanner again. If the
error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear (duplex scanners) lamps.
A rear lamp failure was detected during calibration.
Press Jog to remove the calibration target. Press
Cal and try to calibrate the scanner again. If the
error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear lamps.
Tried to use a calibration target shorter than 12
inches. Press Jog to remove the calibration target.
Use the appropriate calibration target. Press Cal and
try the calibration process again.
Tried to use a calibration target where the front side
is darker than the specification allows. Press Jog to
remove the calibration target. Use the appropriate
calibration target. Press Cal and try the calibration
process again.
Tried to use a calibration target where the rear side
is darker than the specification allows. Press Jog to
remove the calibration target. Use the appropriate
calibration target. Press Cal and try the calibration
process again.
A document has been fed which is off-center or
skewed. Press Run to restart the transport system.
Tried to run the transport system when the scanner
was disabled (other than via the Count Only
function). Enable the scanner from the host and
press Run.
A calibration failure was detected in the front scan
module. Press Cal to calibrate the scanner. If the
error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear (duplex scanners) lamps.
A calibration failure was detected in the rear scan
module. Press Cal to calibrate the scanner. If the
error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear lamps.