A-61070 September 1999
18. Press Enter. Please Wait will be displayed in the status display.
BC Type =
Please Wait
Up to 10 seconds is required for warming the lamps and processing
the data. Within 10 seconds, one of the following messages will
appear in the status display.
Message 1
BC Type =
<Not found>
Not Found indicates that the bar code was not read for one of the
following reasons:
The type of bar code placed on the imaging guide is not the type
indicated in the status display.
Action: Verify the type of bar code placed on the imaging
guide.
The bar code is not positioned properly or faces in the wrong
direction on the imaging guide.
Action: Verify the position of the bar code placed on the
imaging guide.
The bar code quality is poor.
Action: Clean the imaging guides if required.
Press Stop or End to return to the F65 menu.
Message 2
BC Type =
<Partial>
Partial indicates that a start character was recognized, but some
remainder of the bar code was unreadable. The bar code was not
read for one of these reasons:
The bar code is not positioned properly.
Action: Verify the position of the bar code placed on the
imaging guide.
The bar code quality is poor.
Action: Clean the imaging guides if required.
Press Stop or End to return to the F65 menu.
8-13