Code
Message Displayed
E235
Controlled power-down reqrd
E241
Enter correct IA, re-scan
E244
Enter correct IA, re-scan
E245
Enter correct IA, re-scan
E246
Enter correct IA, re-scan
E250
Frnt illumination failure
E251
Rear illumination failure
A-61070 September 1999
Description/Action Required
This message is displayed along with a more
detailed error message.
Turn the side panel switch off.
Turn the main power switch off.
Wait 5 to 10 seconds.
Turn the main power switch on.
Turn the side panel switch on.
If the error repeats, call Service.
The patch document fed conflicts with the Level key
pressed. Verify the current image level and image
address. If necessary, alter the image level or image
address using the Level keys or Next key or press
Run and rescan the patch document.
The T-patch document was fed and then followed by
a 2-patch or 3-patch document which conflicted with
the level of the T-patch. Verify the current image
level and image address. If necessary, alter the
image level or image address using the Level keys,
or Next key or press Run and rescan the T-patch,
2-patch or 3-patch document.
Two T-patch documents were fed one right after the
other. Verify the current image level and image
address. If necessary, alter the image level or image
address using the Level keys or Next key. Do not
scan another T-patch document.
The T-patch document fed conflicts with the level of
the image address entered. Verify the current image
level and image address and if necessary, alter the
image level or image address using the Level keys
or Next key. Do not scan another T-patch document.
A front lamp failure was detected while the front
lamp was illuminated. Press Cal to calibrate the
scanner. If the error persists, verify the optical path is
free of obstructions, clean the imaging guides and
replace the front and rear (duplex scanners) lamps.
A rear lamp failure was detected while the rear lamp
was illuminated. Press Cal to calibrate the scanner.
If the error persists, verify the optical path is free of
obstructions, clean the imaging guides and replace
the front and rear lamps.