Limit Switch Dual Channel Inputs And A Manual Reset - Omron DeviceNet DST1 Series Operation Manual

Safety i/o terminals
Hide thumbs Also See for DeviceNet DST1 Series:
Table of Contents

Advertisement

7-2-5

Limit Switch Dual Channel Inputs and a Manual Reset

An example of the wiring and configuration when using the DST1-ID12SL-1 is shown
below.
Wiring
V
IN0
G
T0
E1
11
S1
GND
12
Configuration
Parameter
group
Safety Input 0
0008
0009
0054
0055
Safety Input 1
0012
0013
Safety Input 11
0052
0053
0064
Test Output 0
0001
Test Output 1
0002
Test Output 2
0003
7-2 Examples of Wiring for Each Application
IN
IN1
T2
11
T1
T1
G
23
S3
S2
24
Parameter name
Safety Input 0 Channel Mode
Safety Input 0 Test Source
Dual Channel Safety Input 0/1 Mode
Dual Channel Safety Input 0/1 Discrepancy Time 100 x 10 ms
Safety Input 1 Channel Mode
Safety Input 1 Test Source
Safety Input 11 Channel Mode
Safety Input 11 Test Source
Dual Channel Safety Input 10/11 Mode
Test Output 0 Mode
Test Output 1 Mode
Test Output 2 Mode
E1: 24-V DC Power Supply (S8
S1: Safety Limit Switch (D4D or D4B)
(positive opening mechanism)
S2: Limit switch
S3: Reset switch
Test pulse from test output
Test Output 0
Dual Channel Equivalent
Test pulse from test output
Test Output 1
Used as standard input
Not Used
Single Channel
Pulse Test Output
Pulse Test Output
Power Supply Output
)
Value
7-7