Test Outputs - Omron DeviceNet DST1 Series Operation Manual

Safety i/o terminals
Hide thumbs Also See for DeviceNet DST1 Series:
Table of Contents

Advertisement

1-3-3

Test Outputs

Item
Test output mode
Any of the following five modes can be selected according to the external input
device.
Output status after
Sets the output state of the test output when a communications error occurs.
communications
This parameter is enabled when the Test Output Channel Mode is set to Standard
error
Output or Muting Lamp Output.
Short-circuit
Supported.
detection
Broken wire
Supported.
detection of
This setting is valid when Test Output Mode is set to Muting Lamp Output.
external indicator
Not Used
The corresponding test output is not used.
Standard Output Specifies connecting to the input for a muting lamp or PLC.
Used as a monitor output.
Pulse Test
Specifies connecting a device with a contact output in
Output
combination with the safety input.
Power Supply
Specifies connecting to the power supply terminal of a safety
Output
sensor. The voltage supplied from the test output to the I/O
power supply (V, G) is output.
Muting Lamp
Specifies a muting lamp output.
Output
When the output is ON, disconnection of the muting lamp can be
(terminal T3
detected.
only)
Description
1-3 Functions
1-9