YASKAWA CIMR-MC5A20P4 Instruction Manual page 205

Table of Contents

Advertisement

D
Fig 7.37 shows a wiring example of external winding change.
3
R
S
230 V
T
VS--626MC5
From CNC
Winding change
7
8
Common
11
D
D
Auto-Winding Change Method
J
This method can be used when the multi-function digital input is not set to "80."
The selection of the motor 1 and motor 2 is conducted internally by preset constants, such as winding
change frequency (P1-01) and winding change hysteresis ( P1-02).
Winding change frequency: P1-01
D
Settings
Setting
0
Motor 1 constants (E1, E2) are used for Y-winding, and motor 2 constants (E3, E4, E5) are used
for -winding
1
Motor 2 constants (E3, E4, E5) are used for Y-winding, and motor 2 constants (E1, E2) are used
for -winding
1
230 V
U
V
W
0 V
+24 VDC
9
Supply
10
MC Answerback
Fig
Sample Wiring for External Wiring Change
7.37
(Open Loop Vector Control Mode)
To use the external winding change method, set the multi-function digital input used for receiving the
winding change signal to "80." This setting enables the selection of Motor 1 constants (E1 and E2)
when the input is open and Motor 2 constants (E4 and E5) when the input is closed.
When using the external winding change method, Auto-Winding constants (P1-01 and P1-02) are not
valid.
User
User
Constant
Name
Number
Winding change fre-
P1-01
quency
Sets winding change frequency when auto-winding change metod is used. Set P1-01 lower than the
max. frequency of the Y-winding.
Function
17 18
2
4
6
24 V
13
14
15
16
HV--75AP3
Megnetic Contactor
Change
during
during
Setting
Setting
Unit
Range
Opera-
tion
0.0 to 400.0
Hz
- 67
7.4 O ptional Functions
Dual Winding
Motor
U
Z
W
X V
Y
B1-02 = 4
H1-05 = 80
H1-06 = 82
H2-01 = 41
A1-02 = 2
E3-01 = 2
Valid Access Levels
Factory
Factory
Open Loop
Setting
Flux Vector
Vector
0.0
A
A
7