Device Status Messages

5-12
Message
What It Indicates
Set Frame Relay Link
Tried to disable the physical
Status to Disable first
port when the logical link
was up; tried to change
Port Status to Disable while
Link Status was enabled.
Value Out of Range
CIR entered for the DLCI is
a number greater than
64,000, or is a special
character.
Excess Burst Size entered
for the DLCI is a number
greater than 999,999, or is
a special character.
DLCI Number entered is
less than 16 and greater
than 1007.
These messages appear in the messages area at the bottom of the screens.
Message
What It Indicates
Already Active
Test selected is already
running.
Backup Active
Backup has been
established and data is
flowing over the alternate
DLCI.
Blank Entries
New had been selected
Removed
from the Administer Logins
screen, no entry was made,
then Save was selected.
Command Complete
Configuration has been
saved or all tests have
been aborted.
Connection Refused
User interface is in use;
access unit already
accessed.
August 1997
What To Do
1. Change Link Status to
Disable.
2. Retry disabling the port.
Enter a valid CIR ( 0 – 64000 ).
Enter a valid Excess Burst Size
( 0 – 999999 ).
Enter a valid number
(16 – 1007 ).
What To Do
Allow test to continue.
Select another test.
Stop the test.
No action needed.
No action needed.
Re-enter the Login ID,
Password, and Access Level.
No action needed.