Displaying Status Information; System And Test Status Messages - Paradyne FrameSaver 9620 User Manual

Hide thumbs Also See for FrameSaver 9620:
Table of Contents

Advertisement

Displaying System Information

Displaying Status Information

System and Test Status Messages

4-4
Procedure
To display statuses:
1. Use the following menu sequence:
Main Menu
Status
2. Select the type of information you want to view
(e.g., Status
PVC Connection Status ).
The following sections provide information about the status information that is
available.
System and test status information is selected from the Status menu:
Main Menu
Status
All messages are listed in alphabetical order.
Health and Status Messages:
These messages appear in the left-most column of the System and Test Status
screen, or the highest priority Health and Status message appears on the last line
at the bottom of the screen (right-most corner).
Message
What It Indicates
Backup Active
Backup has been
established and data is
flowing over the alternate
DLCI.
BRI-B1 Call Profile
ISDN backup call (manual
Disabled
or automatic) could not be
made because the Call
Profile had been disabled.
BRI-B1 Call Profile
ISDN backup call (manual
Invalid
or automatic) could not be
made because the Call
Profile is invalid.
BRI-B1 Call
ISDN backup call (manual
Terminated – Remote
or automatic) was not
successful because it was
terminated at the remote
end.
August 1997
System and Test Status
What To Do
No action needed.
Enable the ISDN Call Profile
( Main Menu
ISDN Call Profiles
1. Verify that the ISDN Call
2. Check that the phone number
1. Check configuration of the
2. Verify that the remote device
3. Verify Calling IDs.
Control
Enable )
Profile identifier is not blank.
associated with the ISDN Call
Profile is valid.
remote device.
is configured answer calls.
9621-A2-GB20-30