Device Status Messages

9121-A2-GB20-00
These messages appear in the messages area at the bottom of the screens.
Message
What It Indicates
Already Active
Test selected is already
running.
Backup Active
Backup has been
established and data is
flowing over the alternate
DLCI.
Blank Entries
New had been selected
Removed
from the Administer Logins
screen, no entry was made,
then Save was selected.
Command Complete
Configuration has been
saved or all tests have
been aborted.
Connection Refused
User interface is in use;
access unit already
accessed.
Please Wait
Command takes longer
than 5 seconds.
Test Active
No higher priority health
and status messages exist,
and a test is running.
User Interface Already
Access to the user interface
in Use
via the COM port or Telnet
is already in use; access to
the interface is denied.
IP address and login of the
user currently accessing
the interface are also
provided.
June 1997
Maintenance and Troubleshooting
What To Do
Allow test to continue.
Select another test.
Stop the test.
No action needed.
No action needed.
Re-enter the Login ID,
Password, and Access Level.
No action needed.
Wait and try again.
Wait until message clears.
Contact service provider if test
initiated by the network.
Wait until the other test ends
and message clears.
Cancel all tests from the Test
screen ( Path: main/test ).
Stop the test from the same
screen the test was started
from.
Wait and try again.
Contact IP address user and
request that they log off.
5-11