Maintenance and Troubleshooting
5-10
Message
What It Indicates
Invalid – Phone
Fewer than seven numbers
number must be at
were entered for the phone
least 7 digits
number associated with the
BRI Service Profile ID
(SPID).
Invalid – SPID must
Fewer than three numbers
be at least 3 digits
were entered for the BRI
Service Profile ID (SPID)
configuration option.
Invalid Test
A conflicting loopback or
Combination
pattern test was in progress
when Start was selected to
start another test, or was
active on the same or
another interface when
Start was selected.
Limit of six Login IDs
An attempt to enter a new
reached
login ID was made, and the
limit of six login/password
combinations has been
reached.
Limit of 40 Links
A management PVC is
Reached
being created and 40 links
already exist.
More than one DLCI is
More than 1 compression
defined for the port.
DLCI record has been
defined for the port, and
Bit Synchronous is set to
Enable.
More than six DLCIs
More than 6 compression
defined for the port.
DLCI records have been
defined for the port, and
Compression is set to
Enable.
Name Must be Unique
Name entered for a
management PVC has
been used previously.
August 1997
What To Do
Enter additional number(s),
Tab to the Clear field, and
re-enter the BRI phone number.
Enter additional number(s),
Tab to the Clear field, and
re-enter the SPID.
Wait until other test ends and
message clears.
Cancel all tests from the Test
screen ( Path: main/ test ).
Stop the test from the same
screen the test was started
from.
1. Delete another login/password
combination.
2. Reenter the new login ID.
Do not create the link.
Delete another link, and try
again.
1. Delete all but one DLCI record
for Port 1.
2. Select Bit Synchronous.
3. Enable.
Delete Port 1 DLCI records until
the number of records is 6 or
fewer.
Enter another 4-character name
for the logical/management link.