Troubleshooting
Fault codes
(cont.)
Display
Const.
Weath.
fault
comp.
code
b0
X
X
b1
X
X
b4
X
X
b5
X
X
b7
X
X
b8
X
X
bA
X
bC
X
bd
X
74
System char-
Cause
acteristics
Burner
Flue gas
blocked
temperature
sensor
shorted out
Control mode
Communica-
as per the de-
tion error;
livered condi-
program-
tion
ming unit
Regulates as
Internal fault
if the outside
temperature
was 0 °C
Control mode
Internal fault
as per the de-
livered condi-
tion
Burner
Boiler coding
blocked
card
Burner
Flue gas
blocked
temperature
sensor break
Mixer "Close"
Communica-
tion fault
extension kit
for heating
circuit M2
Control mode
Communica-
without remote
tion fault
control
Vitotrol re-
mote control,
heating cir-
cuit A1
Control mode
Communica-
without remote
tion fault
control
Vitotrol re-
mote control,
heating cir-
cuit M2
Remedy
Check the flue
gas temperature
sensor
Check connec-
tions and replace
the programming
unit, if required
Replace the con-
trol unit
Replace the con-
trol unit
Plug in boiler cod-
ing card or re-
place, if faulty
Checking the flue
gas temperature
sensor
Check the exten-
sion kit connec-
tions and
encoding; start
the extension kit
Check connec-
tions, cable/lead
and coding ad-
dress "A0"
Check connec-
tions, cable/lead
and coding ad-
dress "A0"