Control functions
Screed function
The screed function enables screeds
to be dried. For this, always observe
the details specified by the screed
manufacturer.
You can select various temperature
profiles.
Observe DIN 4725 2. The report to
be provided by the heating contractor
must contain the following heat up
details:
Temperature profile 1 (DIN 4725 part 4) code "F1:1"
Temperature profile 2 (ZV parquet and flooring technology) code "F1:2"
(cont.)
Heat up data with respective flow
temperatures
Max. flow temperature achieved
Operating condition and outside
temperature during handover.
The function continues after power
failure or after the control unit has
been switched OFF. Heating program
"Heating and DHW" will be started
after the screed function has been ter-
minated or if the address is manually
set to 0.
Function description