Viessmann Vitodens 333 Service Instructions Manual page 46

Compact gas fired condensing boiler. 4.2 to 19 kw natural gas and lpg version
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
21:0
No maintenance inter-
val (hours run) selected
23:0
No time interval for
burner service selected
24:0
The maintenance dis-
play has been reset
25:0
: No outside tem-
perature sensor or re-
mote monitoring
recognised (only for
constant temperature
control units)
28:0
No burner interval igni-
tion
2E:0
Without external exten-
sion
2F:0
Program disabled
30:1
Internal variable speed
circulation pump (auto-
matic adjustment)
31:...
Set speed of the inter-
nal circulation pump
when operated as boiler
circuit pump in %, de-
faulted by the boiler
coding card
32:0
Influence of the signal
"External blocking" on
the circulation pumps:
All pumps in control
function
Note
Generally, the burner will be blocked.
46
Possible change
21:1
The number of hours run
to
before the burner should
21:9999
be serviced is adjustable
from 1 to 9999 h
23:1
Interval adjustable from 1
to
to 24 months
23:24
24:1
Maintenance display (the
value is displayed auto-
matically)
25:1
Outside temperature sen-
sor and fault monitoring
recognised
28:1
The burner will be force
started for 30 s after 5 h
2E:1
With external extension
(automatic recognition)
2F:1
Venting program enabled
2F:2
Filling program enabled
30:0
Internal circulation pump
without variable speed
(e.g. temporarily for ser-
vice)
31:0
Set speed adjustable
to
from 0 to 100%
31:100
32:1
Influence of the signal
to
"External blocking" on
32:15
the circulation pumps:
see the following table