Viessmann Vitodens 333 Service Instructions Manual page 52

Compact gas fired condensing boiler. 4.2 to 19 kw natural gas and lpg version
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
91:0
No external heating pro-
gram changeover via
external extension (only
for weather compen-
sated control units)
95:0
Without Vitocom 100
communication inter-
face
97:0
With LON communica-
tion module: The out-
side temperature of the
sensor connected to the
control unit is utilised
internally (only for
weather compensated
control units)
98:1
Viessmann system
number (in conjunction
with monitoring of sev-
eral systems via
Vitocom 300)
9b:0
Minimum set boiler
water temperature for
external demand
9C:20
Monitoring LON users.
If a user fails to re-
spond, the values de-
faulted inside the
control unit will be used
after 20 min; also, a
fault message is issued
(only for weather com-
pensated control units).
52
Possible change
91:1
The external heating pro-
gram changeover affects
the heating circuit without
mixer
91:2
The external heating pro-
gram changeover affects
the heating circuit with
mixer
91:3
The external heating pro-
gram changeover affects
the heating circuit without
mixer and the heating cir-
cuit with mixer
95:1
With Vitocom 100 com-
munication interface
(automatic recognition)
97:1
The control unit receives
the outside temperature
97:2
The control unit transmits
the outside temperature
98:1
System number adjusta-
to
ble from 1 to 5
98:5
9b:1
Minimum set boiler water
to
temperature adjustable
9b:127
from 1 to 127 °C (limited
by the boiler coding card)
9C:0
No monitoring
9C:5
The time is adjustable
to
from 5 to 60 min
9C:60