SWITCH NAME
SW0
(Piano Key SW)
OFF
8
7
6
5
4
3
2
1
ON
2
NEAX2000 IVS
ISDN System Manual
ND-70919 (E), Issue 1.0
SWITCH
SETTING
NUMBER
POSITION
ON
1
NOTE 3
NOTE 4
OFF
ON
2
NOTE 3
NOTE 4
OFF
ON
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
8
OFF
CHAPTER 4 CIRCUIT CARD INFORMATION
FUNCTION
Source clock signal from network is
sent to the PLO0 input on MP card.
Source clock signal from network is
not sent to the PLO0 input on MP
card.
Source clock signal from network is
sent to the PLO1 input on MP card.
Source clock signal from network is
not sent to the PLO1 input on MP
card.
Remote loop-back
For normal operation
Local loop-back (AIS send)
For normal operation
Set equalizer according to the cable
length between the PBX and the
MDF.
SW0-5 SW0-6 SW0-7
CABLE LENGTH
ON
ON
ON
0-40 m (0-131.2 ft.)
ON
ON
OFF
40-80 m (131.2-262.5 ft.)
ON
OFF
ON
80-120 m (262.5-394 ft.)
ON
OFF
OFF
120-160 m (394-525 ft.)
OFF ON
ON
160-200 m (525-656 ft.)
OFF OFF
OFF
Signal is not sent
Not used
PN-24DTA-C (DTI)
CHECK
(Continued)