(3) Direct In Termination (DIT)
When the ISDN Terminal station number is assigned as the destination of DIT, the system
connects the call with the specified ISDN Terminal or TA on the same bus (2B + D).
ISDN Terminal
Station No. 407
In addition to the programming of
following programming:
START
Assign the data for DIT to the trunk
CM30
numbers assigned by CM07.
Assign the ISDN Terminal station number
to be terminated by Direct In Termination.
END
2
NEAX2000 IVS
ISDN System Manual
ND-70919 (E), Issue 1.0
ISDN Line
Station No. 300
ISDN Terminal
Station No. 400
"Point-to-Multipoint Connection" on Page
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
PBX
ILC
YY=02 Day Mode
•
YY=03 Night Mode
•
YY=40 Mode A
•
YY=41 Mode B
•
(1)
000-255: Trunk No. assigned by CM07
YY=01
(2)
04: Direct-In Termination
YY=04 Day Mode
•
YY=05 Night Mode
•
YY=42 Mode A
•
YY=43 Mode B
•
(1)
000-255: Trunk No. assigned by CM07
YY=01
(2)
X-XXXXXXXX: ISDN Terminal Station
ISDN Terminal Data Programming
TRK
ISDN
214-555-7881
(Office No.)
105, do the
DATA
No.