CHAPTER 3 SYSTEM DATA PROGRAMMING
Event Based CCIS Programming
Access Code/Terminating Number Assignment
for Outgoing Event Based Calls
START
Allocate memory to store the terminating
CM71
numbers to the opposite office.
Assign terminating numbers of the
CM72
opposite office (access code for ISDN line
+ ISDN subscriber number) to the Memory
Slot number allocated by CM71.
END
Page 132
DESCRIPTION
DATA
(1)
66
(2)
XXX YYY
XXX: 000-299: First Memory Slot No.
YYY: 001-016: Number of Memory Slot
allocated
Y=0
(1)
000-299: Memory Slot No.
(2)
Stored No.: XX + , + ZZZ...
XX
: Access Code for ISDN
ZZZ...: ISDN Subscriber No. of Oppo-
site Office (Max. 26 digits)