CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN Terminal Data Programming

Point-to-Point Connection

ISDN Terminal/TA
START
CMAC
Assign the point to point connection as the
Layer 2 data link.
NOTE: When Point-to-Point Connection is selected, the PBX will address the BRI Terminal
with channel select (B1/B2) message. Some BRI Terminals cannot answer the call
with this type of signaling. Some of the BRI Terminals require a Calling Party
Number sent from the PBX. In this case, use Point-to-Multipoint for CMAC YY=01
and CM1B to assign extension number for the BRI Terminal.
Assign the TEI Manual Assignment.
Assign the Extended Passive Bus.
Assign the always activated as the method
of Layer 1 activation.
END
Page 104
MDF
Max. 1965 ft. (600 m)
DESCRIPTION
INITIAL
INITIAL
INITIAL
INITIAL
ILC
DATA
YY=01
(1)
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
(2)
0: Point to Point Connection
YY=02
(1)
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
(2)
0: TEI Manual Assignment
YY=03
(1)
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
(2)
0: Extended Passive Bus
YY=04
(1)
XX Z
XX: 00-15: ICH No.
Z : 0-7: ISDN Line No. of ICH card
(2)
0: Always activated
NEAX2000 IVS
PBX
2
ISDN System Manual
ND-70919 (E), Issue 1.0