9-3. Stopping Operation

CAUTION : BURNS
 Do not touch the engine and surrounding components immediately after
stopping the engine as they are still extremely hot.
(1) Manual Start
Turn the switches and breakers on the load side to OFF position.
1
Turn the breaker on the operation panel to OFF position.
2
The engine cools down for approximately 3 minutes.
3
Press the Stop Mode Button to shut off the engine.
4
Turn the Power Switch to OFF position.
5
< Note >
 Set the Power Switch to OFF position if the generator will not be used for a prolonged period.
If you leave the Power Switch in the OFF position, the standby current may drain the battery.
(2) Auto Start
The engine stops when the RS1/RS2 terminals open.
1
Turn the breaker on the operation panel to OFF position.
2
Press the Stop Mode Button to shut off the engine.
3
Turn the Power Switch to OFF position.
4
< Note >
 Set the Power Switch to OFF position if the generator will not be used for a prolonged period.
If you leave the Power Switch in the OFF position, the standby current may drain the battery.

9-4. Protective Functions

WARNING : INJURY
 Do not open the check door when the Power Switch is in the ON position. It
will cause injury by rotating parts such as cooling fans and fan belt.
 Always turn the Power Switch to the OFF position and stop the engine, then
close and lock OPERATION PANEL DOOR before checking or maintaining
the engine or any equipment.
CAUTION : BURNS
 Do not touch the engine and surrounding components immediately after
stopping the engine as they are still hot.
 Hot steam gushes out from the coolant subtank if the generator overheats.
Do not touch the coolant subtank.
This generator is equipped with functions to automatically stop operation when there is
a fault/malfunction during operation, and this is to warn the operator of the fault location
by use of indicator lamps or the Operation Display. Check the fault location when the
engine is automatically stopped or an indicator lamp illminates to stop the engine or
appear warning on the Operation Display.