Shindaiwa DG25MK Assembly And Instruction Manual page 38

Diesel engine generator
Hide thumbs Also See for DG25MK:
Table of Contents

Advertisement

(3) Air Filter Element Cleaning/Replacement
First Time (clean)
Thereafter (clean)
Replace
Remove the air cleaner clips and cleaner cap.
1
Remove the element.
2
Clean or replace the element. Replace by
3
performing the above procedures in reverse
order.
< Note >
 Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
 Replace the elements earlier if using in an excessively dusty location.
 Do not add oil as this generator uses a dry element.
 Clear foreign material by pinching the vacuator valve once a week in normal operating
conditions or daily if operating in a location that is excessively dirty or dusty. Wipe away any
dirt or moisture that has adhered to the parts.
 Never touch the elements for any reason except cleaning.
 Element part no.: R1401-42271 (Kubota part no.)
 Cleaning the air filter element
If dry dust is adhering : Blow compressed air from inside the element.
If carbon or oil is adhering : Replace with new parts.
(4) Draining Water from the Water Separator
Check
Clean
Every 100 hours
Drain water when the float (red) inside the cup is at
the water draining position.
Close the fuel valve.
1
Loosen the faucet and then loosen the air bleeder
2
plug.
After water has been drained, tighten the
3
faucet and
air bleeder plug.
If foreign material is adhering to the gauze filter in
4
the cup, remove the cup, float and gauze filter,
and clean by blowing compressed air from the
inside of the gauze filter.
Reassemble the gauze filter, cup and float to their original locations.
5
< Note >
 When attaching the cup, check that there is no foreign material adhering to the O-ring.
 After attaching, open the fuel valve, and be sure to always start the engine and check that
there is no fuel leakage.
 If water is accumulate in the cup, draining water from the fuel tank. (Refer to section "(6)
Draining Water from the Fuel Tank
50 hours
100 hours
once in 6 times cleaning or
Every 1 year
Daily
".)
35
Air Cleaner
Cap
Air Filter Elements
Air Cleaner Cap
Vacuator Valve
Air
Bleeder
Plug
Close
Open
Gauze Filter
Fauce
Water Drain Level
t
Float
(Red)
Clip
Fuel
Valve
Cup

Advertisement

Table of Contents
loading