Shindaiwa DG25MK Assembly And Instruction Manual page 33

Diesel engine generator
Hide thumbs Also See for DG25MK:
Table of Contents

Advertisement

Protection Feature List
Earth
Action
Leakage
No.
Relay
Abnormality
Active
Low Oil
1
Pressure
High Coolant
2
Temperature
Air Filter
3
Clogging
4
Overload
5
Fail to Start
6
Water In Fuel
Charge Alt
7
Failure
8
Fuel Level Low
9 Current Leakage
*
indicates the automatic activation.
Engine
Breaker
Automatic
Trip
Shutdown
Warning
Controller
Indicator
display
Flash
Activate due to low oil pressure in the engine
Default : 0.49  100 kPa
Activates due to high water temperature in the
engine. Default : 115°C
The element is clogged making it necessary to
clean or replace the element.
Activates in overload
Flashes when at approx. 80% of rated output.
Load rejection when the rated output is
exceeded.
The engine fails to start three times
When the water separator is full of water.
Activates in battery charge Impossible
The amount of fuel is small
Activates in current leakage
30