2. Specifications

2-1. Specifications
Model
Generating Type
Rated Frequency
Rated Output
Rated Voltage
Rated Current
Winding
Power factor
Insulation class
Excitation
No. of poles
Types
Model (Manufacturer)
No. of Cylinders (bore x stroke)
Continuous rated output
Rated speed
Displacement
Combustion system
Cooling method
Lubricating method
Starting method
Fuel
Lubricant oil
Fuel tank capacity
Lubricant volume (Full)
Cooling water volume
Starting motor capacity
Charging dynamo capacity
Battery
Length
Width
Height
Dry Weight
Installed Weight
*1: For the output at 130kVA or below, set the voltage selector at 380V. For 136kVA or below,
set the voltage selector at 200V.
*2:The values in brackets are optional data, when modified to 200/220V by the dealers only.
As default 3-phase output is set at 400/440V, contact your authorized distributor to adjust
the terminal lug setting if necessary to obtain 200/220V for 3-phase output.
Unit
Rotating Field, Brushless 3-Phase
-
Hz
50
kVA
125
100
kW
V
400 [200] *2
A
180 [361] *2
-
%
-
-
Self-Excitation(Brushless)
-
-
Vertical Water-cooled 4-cycle Diesel Engine
-
6D16-TLE2D (MITSUBISHI)
mm
kW
113
PS
153.6
-1
min
1500
L
-
(Turbocharged with Intercooler)
-
-
-
Diesel Fuel (ASTM No. 2-D)
-
-
L
L
L
V-kW
V-A
-
mm
mm
mm
kg
kg
5
DG150MM-400
Synchronous Alternator
60
150*1
120
440 [220] *2
197[394] *2
3-phase, 4-wire
3-phase 80
F
4
6 (118 X 115)
135
183.5
1800
7.54
Direct Fuel Injection
Radiator
Forced lubrication
Electric start
CD or CF-4 class
250
20
26
24 – 5
24 - 35
105E41R x2
3230
1100
1500
2270
2540