 Check that the surrounding area is safe before starting the engine.
 When there are multiple workers who are working together, they must mutually
signal each other before starting the engine.
 Do not use in an area with high temperature or humidity, or an area with a large
amount of dust.
 Do not open any doors during operation. Operating with door open can negatively
affect cooling effect, resulting in an equipment malfunction.
 Use ear protection if the level of noise is high. Failure to do so could result in
hearing damage.
 Please be careful about a strong wind and the opening and shutting of the door at
the sloping place enough. A door is open suddenly and is closed, and a finger might
be sandwiched.
Turn the circuit breaker in the operation
1
panel to "OFF".
Check that the frequency set by the
2
selector switch and equipment shoud be
identical.
< Note >
 Frequency being set at the frequency
selector switch and actual output shall
be reconciled otherwise it cannot
preserve the rated voltage.
Set the throttle lever to "IDLING".
3
Turn the starter switch to "START", and start the engine.
4
< Note >
 In a cold environmental condition, turn the starter switch to "PREHEAT"
position.The glow lamp converts to red after approx. 15 sec., after preheating
completes.
 Do not leave the starter key at "PREHEAT" over 30 sec. otherwise it may
damage the preheating feature.
 Do not continue operation the starter motor for 10 sec. or more.
 Remain an interval for 30 sec. each at least if the starter should continuously
operated.
After starting the engine, remove your hand from the starter switch.
5
Let engine idles for approximately for five minutes.
6
Set the throttle lever to "RUN"
7
screw.
Rated frequency
50Hz(1,500min
60Hz(1,800min
8
Adjust the voltage regulator dial to the specified voltage.
50Hz Operation
60Hz Operation
* The values in brackets are for when set to 200/220V.
Turn the breaker to "ON to start AC power delivery.
9
and adjust frequency with the frequency adjust
No-load frequency
-1
)
52.5Hz(1,575min
-1
)
63.0Hz(1,890min
400V [200V]
440V [220V]
26
Throttle Lever
Preheat
Lamp
Frequency
Adjust Screw
-1
)
-1
)
Circuit
Breaker
Starter
Switch