< Note >
Check that the surrounding area is safe before starting the engine.
When there are multiple workers who are working together, they must mutually
signal each other before starting the engine.
Do not use in an area with high temperature or humidity, or an area with a large
amount of dust.
Do not open any doors during operation. Operating with door open can negatively
affect cooling effect, resulting in an equipment malfunction.
Use ear protection if the level of noise is high. Failure to do so could result in
hearing damage.
Please be careful about a strong wind and the opening and shutting of the door at
the sloping place enough. A door is open suddenly and is closed, and a finger might
be sandwiched.
Turn the circuit breaker in the operation
1
panel to "OFF".
Check that the frequency set by the
2
selector switch and equipment shoud be
identical.
< Note >
Frequency being set at the frequency
selector switch and actual output shall
be reconciled otherwise it cannot
preserve the rated voltage.
Set the throttle lever to "IDLING".
3
Turn the starter switch to "START", and start the engine.
4
< Note >
In a cold environmental condition, turn the starter switch to "PREHEAT"
position.The glow lamp converts to red after approx. 15 sec., after preheating
completes.
Do not leave the starter key at "PREHEAT" over 30 sec. otherwise it may
damage the preheating feature.
Do not continue operation the starter motor for 10 sec. or more.
Remain an interval for 30 sec. each at least if the starter should continuously
operated.
After starting the engine, remove your hand from the starter switch.
5
Let engine idles for approximately for five minutes.
6
Set the throttle lever to "RUN"
7
screw.
Rated frequency
50Hz(1,500min
60Hz(1,800min
8
Adjust the voltage regulator dial to the specified voltage.
50Hz Operation
60Hz Operation
* The values in brackets are for when set to 200/220V.
Turn the breaker to "ON to start AC power delivery.
9
and adjust frequency with the frequency adjust
No-load frequency
-1
)
52.5Hz(1,575min
-1
)
63.0Hz(1,890min
400V [200V]
440V [220V]
26
Throttle Lever
Preheat
Lamp
Frequency
Adjust Screw
-1
)
-1
)
Circuit
Breaker
Starter
Switch