Diesel engine generator
Table of Contents

Advertisement

< Note >
 Connect a lamp that is DC24V/2A/48W or less to the Auxiliary Lamp Terminal.
 The pre-caution
lamp flashes when more than 80% of the rated output lasts for 20
seconds.
(4) 400/440V output Lamp
This lamp illuminates if 400/440V are supplied from the output terminal
and turns off if 200/220V are supplied. Check the rated voltage of the
device being used.
< Note >
 Check that the voltages of the generator output setting, output
terminal connection and load power source are consistent.
Switches
(1) Starter Switch
① Stop
When the switch is set to this position, all power will be off.
The switch must be set to this position to remove the key.
② Run/Preheat
The switch must be set to this position during operation.
This position is also used during cold season, to preheat GlowPlug.
< Note >
 Do not leave the switch to this position, while the engine is stopped.
Otherwise the battery is discharged.
③ Preheat
This position is used during cold season, to preheat Glow Plug
④ Start
This position is to start the engine. When the key is released, the
setting will automatically return to <Run> position.
(2) Frequency Selector Switch
This switch functions a covert the frequency for 50Hz or 60Hz. It locates
inside of the operation panel. Loosen the two screws and open the
operation panel. The settimg and frequency in equipment shoud be
identical.
< Note >
 Control panel should only be opened by an authorized service
technician.Extreme caution should be used when opening the control
panel to check that no loads are connected before using the
frequency switch or touching any components.
13