Generac Power Systems PowerPact G0065201 Installation Manuallines page 22

50 hz air-cooled generators 5.6 kva
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
Fuel Conversion/Gas Connections
Fuel Consumption
Generator
5 / 5.6 kVA
3
* Natural gas is in ft
/h / cm
3
** LP is in gal/h / l/h / ft
*** Values given are approximate. Use the appropriate spec sheet or Owner's Manual for specific values.
Verify that gas meter is capable of providing enough fuel flow to include household appliances and all other loads.
NOTE: The gas supply and pipe MUST be sized at 100% load BTU / Megajoule rating.
Always refer to the Owner's Manual for the proper BTU, Megajoule and required gas pressures:
Natural Gas:
3
BTU = ft
/h x 1000
Megajoules = m
Liquid Propane Vapor
3
BTU = ft
/h x 2500
Megajoules = m
18
Natural Gas
1/2 Load
Full Load
81 / 2.29
120 / 3.42
3
/h
/h
3
/h x 37.26
3
/h / hour x 93.15
LP Vapor
1/2 Load
0.67 / 2.54 / 24.4
Installation Guidelines for 50 Hz PowerPact™
Full Load
1.14 / 4.32 / 41.5