Table 11. Troubleshooting Tips
No.
Issue / Problem
When the thermostat is first started and
1a
is stuck on the splash screen.
When the thermostat is first started and
1b
is stuck on a blank screen.
Screen turns blue and the following
message appears "Thermostat is un
able to establish communication to
the indoor unit or other devices.
1c
Probable cause is a miss wire
Please verify all the wiring and con
nections and restart the system".
- No electric heat operation.
- The thermostat system setting
does not offer a emergency heat
2
choice on an HP system.
- The thermostat does not offer any
"heat" choice on an AC system with
air handler with electric heat.
Thermostat Displays System Waiting
message and the furnace does re
3
spond to a heating demand (no red
critical alert icon or alert messages
are displayed on the thermostat).
Outdoor temperature is not displayed
4
on the thermostat.
A humidifier was added to the system
as non-communicating equipment
5
and the thermostat does not provide
the ability to adjust the RH set point.
The non-communicating outdoor unit
is part of the system, but the thermo
6
stat does not display the outdoor unit.
High Balance Point and Low Balance
Point are not listed as a menu item to
7
adjust the set point on the thermostat
of the heat pump system.
iComfort thermostat does not show a
choice for Dew Point Control Humidi
8
fication mode (only Basic and Preci
sion choices).
The iComfort does not display an
alert code message, but the furnace
9
or unit control displays a diagnostic
code.
The iComfort thermostat does not dis
play the Model # and or Serial # in
10
door or outdoor unit.
A non-communicating 2-stage out
door unit was added to the system
11
but the unit only runs in 2nd stage.
Transfer the Model #, Serial # and
12
system settings to a replacement
control.
®
iComfort Wi-Fi
Bold text indicates a button, or text display on the thermostat.
Possible Cause
Thermostat is possibility incorrectly
wired and cannot find an iComfort-
enabled indoor unit.
Electric heat was not manually con
figured configured at the Air Handler
Control (AHC) before the iComfort
®
Wi-Fi
system discovery process at
initial power-up.
The furnace is in "watchguard"
mode (moderate alert) and will not
display the red critical alert icon nor
be displayed in the homeowner alert
button.
Outdoor Temp Display must be en
abled to display the outdoor temper
ature on the home screen.
Humidification Control Mode is set
for "Display only" which will not al
low the iComfort system to control
the humidifier.
The outdoor unit was not added as
a non-communicating unit during ini
tial system setup.
Balance Point Control must be en
abled to display as the High Balance
Point and Low Balance Point in the
menu and provide the ability for the
installer to adjust the set point.
Dew Point Control will only be dis
played if the system has an outdoor
sensor.
The red Critical Alert icon and
homeowner alert button do not dis
play non-critical alerts.
The iComfort control was replaced
with a replacement control before
the iComfort system was initially
setup or configured.
The "W915 2 Stage Compr" clip
pable option link on the furnace or
air handler control must be cut when
used with a non-communicating
2-stage outdoor unit.
The iComfort system is capable of
copying settings from the previous
configuration to the new compatible
device (control) found.
Page 33
Corrective Action / Comments
- Stuck splash screen due to incorrect wiring will occur on thermostats with
firmware version 2.00 or 2.02.
- Thermostat did not find an Indoor Unit. Make sure there is an iComfort
indoor unit on the system. Check R, i+, i- and C connections, ohm wires
and cycle power. Replace indoor unit control board if there is no response.
- Stuck splash screen due to incorrect wiring will occur on thermostats with
firmware version 2.01.
- Thermostat did not find an Indoor Unit. Make sure there is an iComfort
indoor unit on the system. Check R, i+, i- and C connections, ohm wires
and cycle power. Replace indoor unit control board if there is no response.
- Blue screen with notification text that could be due to incorrect wiring will
occur on thermostats with firmware version 2.10.
- Thermostat did not find an Indoor Unit. Make sure there is an iComfort
indoor unit on the system. Check R, i+, i- and C connections, ohm wires
and cycle power. Replace indoor unit control board if there is no response.
- Manually configure to discover the electric heat section(s) on the air hand
ling (see Page 38 or CBX32MV or CBX40UHV manual for details).
- Re-setup the iComfort system by selecting the setup button in the Installer
program and press start to begin system discovery; then reconfigure the
system.
- Go to the installer program alert button to view all alerts and details about
those alerts.
- If the furnace is in "watchguard" mode, the furnace can be reset from the
Home screen by setting the thermostat system settings to off for 20 sec,
then back to heat. Then initiate a new heat demand.
On the home screen, press the right arrow
then press the display settings button. Click on outdoor temp display button
to toggle ON.
- In the installer program, select the equipment button. Select "System"
from the device list using the up/down arrows and press the edit button.
Use up/down arrows to select Humidification Control Mode from the list.
Select the desired humidifier control mode: Basic, Precision, or Dew
Point. (Basic is the most popular) and press the save button. Follow the
red instructions then exit the system.
- If Humidification Control Mode is not offered as a menu item choice, the
Humidifier must be added to the iComfort system using the Add or Re
move Non-communicating equipment screen under the thermostat
installer program in the setup button.
In the thermostat installer program select the setup button and follow the on
screen instructions until you reach the Add or Remove Non-communicating
equipment screen; press yes. Select Outdoor Unit Type from the menu and
press the edit button. Select 1 Stage AC Unit or 2 Stage AC Unit and press
save. Follow the red instructions then exit the system.
- In the installer program select the equipment button, then scroll down to
system device to System and press edit. Scroll down the menu item
choices to Balance Point Control and press edit. Select enable and
press save. High Balance Point and Low Balance Point are now listed;
adjust the balance point settings and press save.
- If Balance Point Control is not shown as a menu item choice, the system
does not have/recognize an outdoor sensor or the system is not a heat
pump.
- Add an outdoor sensor to the system and connect to the outdoor sensor
terminals on the indoor unit.
- iComfort system is not able to read the outdoor temperature sensor in the
iComfort outdoor unit, check outdoor sensor.
Go to the installer program alert button to view all alerts and details about
those alerts.
- Replacement iComfort controls do not have the Model # or Serial # loaded
in the control.
- The Model # and Serial # cannot be added to the control.
- System will still operate normally.
Cut the "W915 2 Stage Compr" option link on the furnace or air handler con
trol.
Reconfigure the system using the installer program and select the setup
button. The system will go through the system discovery process. The ther
mostat will display missing devices (old control) and found compatible
devices (new control). Press the next button to accept the new device and
copy the settings. Thermostat will display Settings were copied after suc
cessfully copying the information to the new control. See section title "Recon
figuring a system" in this manual.
7-Day Programmable Communicating Thermostat
table continued on next page