Parameter Name:
Balance Point Control
Min HP heating demand
Humiditrol Comfort Adjust
Humidification Control Mode
Max Humidification Setpoint
Auto Changeover - Humidif. Dead-band
Humiditrol and Aux Dehum Min Run Time
HP Heating Lockout Time
Heat Cool Stages Locked In
*1st Stage Differential
*2nd Stage Differential
*3nd Stage Differential
Stage Delay Timers
*2nd Stage Delay
*3rd Stage Delay
Min De-humidification Setpoint
Outdoor Temperature Reading Calibration
Zoning Gas heating DAT Cool down Target
Zoning Anticipated Discharge Air Temperature Adjustment
Zoning Target Supply Air Temp for Cooling
Zoning Target Supply Air Temp for Gas/Electric Heating
Zoning Target Supply Air Temp for HP Heating
Zoning Supply Air Temp Limit for Cooling
Zoning Supply Air Temp Limit for Gas/Electric Heating
*Number of stages shown in thermostat is dependent on equipment that is installed. Electric heat will bring on 2 elements at a time if available.
Lock in 2nd stage HP by Outdoor Temp
Zone 1 First Stage Differential
Zone 2 First Stage Differential
Zone 3 First Stage Differential
Zone 4 First Stage Differential
Zone 1 Continuous Blower CFM
Zone 2 Continuous Blower CFM
Zone 3 Continuous Blower CFM
Zone 4 Continuous Blower CFM
Zone 1 Cooling CFM
Zone 2 Cooling CFM
Zone 3 Cooling CFM
Zone 4 Cooling CFM
Zone 1 Heating CFM
Zone 2 Heating CFM
Zone 3 Heating CFM
Zone 4 Heating CFM
Parameter Name:
Equipment Name
Compressor Short Cycle Delay
High Normal Cooling Airflow (XC25 only)
Low Normal Cooling Airflow (XC25 only)
Dehum Airflow Adjustment Adder
®
iComfort Wi-Fi
Table 3. System Devices > Air Conditioner
system devices
To adjust a setting,
System
highlight it, then press
Air Conditioner
Edit
Furnace
Air Conditioner
Thermostat
Default
Outdoor Unit
300 Seconds
1600
750
0
Default
Disabled
30
Maximum
Maximum, Minimum and Midpoint
Overcooling
Display Only, Precision, Precision Dew Point
Basic
Control, Basic, Basic Dew Point Control
45ºF
5ºF
15 minutes
120 minutes
Disabled
1.0ºF
1.0ºF
1.0ºF
Enabled
20 Minutes
20 Minutes
40
0ºF
100ºF
60ºF
50ºF
100ºF
90ºF
40ºF
140ºF
Off, 40ºF (4ºC), 45ºF (7ºC), 50ºF (10ºC), 55ºF
Off
1.0ºF
1.0ºF
1.0ºF
1.0ºF
To be determine by equipment capacity.
about
resetAll
edit
next
back
Parameter Value Setting
(keyboard input screen = up to 35 characters in string)
60 to 300 Seconds
450 to 2150
450 to 2150
0 to 30
7-Day Programmable Communicating Thermostat
Page 7
Parameter Value Setting
Disabled or Enabled
30 to 100ºF
Overcooling
15 to 45ºF
5 to 10ºF
5 to 30 minutes
60 to 240 minutes
Enabled, Disabled
0.5 to 3ºF
0.5 to 8ºF
0.5 to 8ºF
Enabled, Disabled
5 to 120 Minutes
5 to 120 Minutes
40 to 60 RH%
-10 to 10ºF
80 to 110ºF
0 to 120ºF
50 to 60ºF
100 to 130ºF
85 to 110ºF
35 to 45ºF
140 to 160ºF
(13ºC)
0.5 to 3.0ºF
0.5 to 3.0ºF
0.5 to 3.0ºF
0.5 to 3.0ºF
Increment
5
1ºF
1ºF
5 minutes
30 minutes
0.5ºF
0.5ºF
0.5ºF
5 Min
5 Min
1
1ºF
1ºF
10ºF
1ºF
5ºF
1ºF
2ºF
5ºF
0.5ºF
0.5ºF
0.5ºF
0.5ºF
Increment
60 Sec
25
25
1