Lennox iComfort G71MPP-03 Setup Manual page 9

Hide thumbs Also See for iComfort G71MPP-03:
Table of Contents

Advertisement

Parameter Name
Equipment Name
Airflow Profile - Cooling
Continuous Indoor Blower Airflow
De-humidification Airflow %
Heating Indoor blower OFF delay
Heating Indoor blower ON delay
Cooling Indoor blower OFF delay
Cooling indoor Blower ON Delay
HP Indoor Blower OFF Delay
HP Indoor Blower ON Delay
Heating Airflow Control Type
Low Heating Airflow
High Heating Airflow
Gas Heat Airflow Settings
Heating Airflow Control Type
(variable capacity furnaces only)
Low Heating Airflow
(CFM @ min. heat)
High Heating Airflow
(CFM @ 100% heat)
Low Heating Discharge Air
Temperature (DAT @ min heat)
(variable capacity furnaces only)
High Heating Discharge Air
Temperature (DAT @ 100% heat)
(variable capacity furnaces only)
* - Default DAT value is rounded to the closest number on 5 deg F resolution and limited by Minimum and Maximum value.
Cooling Airflow Settings
High Cooling Airflow
(CFM @ 100% cool)
Low Cooling Airflow
(CFM @ lowest cool stage)
®
iComfort Wi-Fi
Table 6. System Devices > Furnace
system devices
To adjust a setting,
System
highlight it, then press
Heat Pump
Edit
Furnace
Furnace
Thermostat
Default
Min.
Max.
A
-
1-
70
60
8-
DIP SW
60
180
30 sec
15
45
0 sec
0
30
2 sec
0
10
45 sec
0
60
0 sec
0
30
Selections available if discharge air temperature sensor is installed (fixed cfm and fixed discharge air temperature).
Low and high heating air flow is dependent on model of indoor unit
0 – Fixed
0
1
CFM
DIP SW
DIP SW
See furnace docu
mentation (IOM or
Product Specifica
DIP SW*
tions) for size spe
cific information
DIP SW*
Min
Max
Outdoor unit
CFM
CFM
tons
Min
Max
400CFM
CFM
CFM
Min
Max
(See Note 1
CFM
CFM
at end of
Min
Max
table)
CFM
CFM
about
resetAll
edit
back
Incr.
Dependency
Note or Options
Dependent on model number of installed unit
A:ON:50%/30S,82%/7.5min OFF:5-%/30S
B:ON:82%/7.5min; OFF: No delays
-
None
C:ON: No delays; OFF: 45sec delay
D:No delays
nnnn CFM (See Note 3 at end of table)
1
None
10
None
DIP switch setting in Non-comm.
5
None
45 sec fixed in Non-Comm. IFC
Outdoor Unit
2
Not used on Non Comm. IFC
present
Outdoor Unit
1
2 sec fixed in Non-Comm. IFC
present
5
Heat Pump present Not used on Non Comm. IFC
5
Heat Pump present Not used on Non Comm. IFC
0 (Fixed CFM)
1
DATS installed
1 (Fixed DAT)
25
Heating Airflow
Control Type = 0
25
See furnace documentation (IOM or Product Specifica
tions) for size specific information
5
Heating Airflow
Control Type = 1
5
25
1/2 HP blower
Outdoor Unit
present
25
1 HP blower
25
1/2 HP blower
2+ stage Outdoor
Unit present
25
1 HP blower
7-Day Programmable Communicating Thermostat
Page 9
next

Advertisement

Table of Contents
loading

Table of Contents