Lennox iComfort G71MPP-03 Setup Manual page 8

Hide thumbs Also See for iComfort G71MPP-03:
Table of Contents

Advertisement

Parameter Name:
Equipment Name
Compressor Short Cycle Delay
Defrost Termination Temp
Compressor Shift Delay On/Off
High Normal Cooling Airflow (XP25 only)
Low Normal Cooling Airflow (XP25 only)
High Normal HP Heating Airflow (XP25 only)
Low Normal HP Heating Airflow (XP25 only)
Dehum Airflow Adjustment Adder
Parameter Name:
Equipment Name
Electric Heating Airflow
High Cooling Airflow
Airflow Profile - Cooling
Continuous Indoor Blower Airflow
Heating Indoor Blower OFF Delay
Heating Indoor Blower ON Delay
Cooling Indoor Blower OFF Delay
Cooling Indoor Blower ON Delay
Note
All communicating Installer Parameters default CFM values based on DIP switch setting (non-communicating value) are calculated using the CFM
conversion tables and rounded up to closest number on 25 CFM resolution.
507152-01
Table 4. System Devices > Heat Pump
system devices
To adjust a setting, high
System
light it, then press Edit
Heat Pump
Furnace
Heat Pump
Thermostat
Default
Outdoor Unit
300 Seconds
50ºF
On
1600
750
1600
750
0
Table 5. System Devices > Air Handler
system devices
To adjust a setting,
System
highlight it, then press
Heat Pump
Edit
Air Handler
Air Handler
Thermostat
about
resetAll
edit
next
back
Parameter Value Setting
(keyboard input screen = up to 35 characters in string)
60 to 300 Seconds
50ºF to 100ºF
On, Off
450 to 2150
450 to 2150
450 to 2150
450 to 2150
0 to 30
about
resetAll
edit
next
back
Default
Air Handler
nnnn CFM (See Note at
NOTE: CFM Default and Values Settings
end of table)
are dependent on the tonnage of the unit
nnnn CFM (See Note at
NOTE: CFM Default and Values Settings
end of table)
are dependent on the tonnage of the unit
1: No Delays,
2: ON: No delays; OFF: 45 sec delay
1
3: ON: 82%/7.5min; OFF: No delays
4: ON: 50%/30s,82%/7.5min;
OFF:50%/30s
nnnn CFM (See Note at
NOTE: CFM Default and Values Settings
end of table)
are dependent on the tonnage of the unit
10 sec
0 sec
0 sec
2 sec
Page 8
Parameter Value Setting
(keyboard input screen)
0 to 10 Seconds
0 to 5 Seconds
0 to 30 Seconds
0 to 10 Seconds
Increment
60 Sec
10ºF
25
25
25
25
1
Increment
5CFM
5CFM
10CFM
1 sec
1 sec
2 sec
1 sec
7/2013

Advertisement

Table of Contents
loading

Table of Contents