Refitting the Output Board

Note

Information to the Replacement Output Board

4.16 Disassembly and Reassembly
Refitting the output board is the reverse procedure of removal. Please
note the following:
Carefully mount the coil with the help of the plastic holder, p/n
08114-22304, and the screw, p/n 0515-1060. Do not overtighten the
screw, because the plastic holder can break.
Carefully and gently push back the hybrid module guiding shield, p/n
08114-23101, into place, and secure it with the 2 screws.
The replacement output board is delivered with an additional hybrid
module guiding shield which is only required for transportation of the
replacement board, or if the original guiding shield is broken when
removed.
Cut and remove the tie-wrap which secures the coil to the board
during transportation.
Remove the antistatic foam at the non-component-side of the output
board, it is only required during transportation.