I/O Connector Power Status Output Details
This section provides details of the Power Status Output relay.
The Power Status Output is a relay between pin 1 and 2 of the I/O Connector.
l Power ON Power Status Output Operation
This section provides power ON details of the Power Status Output operation.
The Power Status Output turns ON to indicate that the system has been shut down and the power
supply to the Panel PC can be turned OFF.
If power is not turned OFF, the Power Status output will turn OFF when the Panel PC is turned ON.
The Power Status Output is ON A when the Panel PC has been used and has not been discon-
nected from the power supply.
The Power Status Output is OFF B when the Panel PC has been disconnected from the power
supply.
Closed (ON)
A
Relay
Open (OFF)
Closed (ON)
B
Relay
Open (OFF)
Additional Information
Refer to 5-4-4 Wire the I/O Connector on page 5-37 for I/O connector wiring details.
l Power OFF Power Status Output Operation
This section provides power OFF details of the Power Status Output operation.
The Power Status Output turns ON to indicate that the system has been shut down and the power
supply to the Panel PC can be turned OFF.
If power is not turned OFF, the Power Status output will stay ON A . It will turn OFF when the
Panel PC is turned ON.
If power is turned OFF, the Power Status Output will turn OFF B .
NY-series Industrial Panel PC Machine Controller Hardware User's Manual (W557)
Product OFF
Power up
start
Power supply has
been disconnected
Product ON
4 Specifications
4
4-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac ny532-1 00 seriesSysmac ny532-5400

Table of Contents