Enabling Button Of The Hand-Held Terminals Indracontrol Veh 30.1/30.2 Or Vch 08.1; Stop Button Of The Hand-Held Terminals Indracontrol Veh 30.1/30.2 Or Vch 08.1; Further Modules - Bosch Rexroth IndraControl VAM 11.1 Project Planning Manual

Table of Contents

Advertisement

DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels

Enabling Button of the Hand-Held Terminals IndraControl VEH 30.1/30.2 or VCH 08.1

STOP Button of the Hand-Held Terminals IndraControl VEH 30.1/30.2 or VCH 08.1

6.3

Further Modules

The hand-held terminals IndraControl VEH 30.1/30.2 or VCH 08.1 are provided
with a 2-circuit, 3-stage enabling button operated by two actuators integrated
in the rear of the housing. Further information is contained in the documenta‐
tions of the hand-held terminals IndraControl VEH30.1 (DOK-SUPPL*-
VEH*30.1***-PR02-EN-P),
VEH*30.2***-PR01-EN-P)
VCH*08.1***-PR01-EN-P).
The connection module for the hand-held terminals VEH 30.1/30.2 or VCH 08.1
is equipped with an automatic STOP circuit jumpering. Thus, the operator can
connect or disconnect the hand-held terminals IndraControl VCH 08.1 or VEH
30.1/30.2 via the connection module without causing an unintended stopping
of the installation.
NOTICE
Before commissioning the IndraControl VEH 30.1/30.2 or VCH 08.1 observe
that the STOP button is NOT pressed.
For more detailed information about the safety concept and the
connection of the stop and enabling circuits of the IndraCon‐
trol VEH 30.1/30.2 or the VCH 08.1, please refer to the documen‐
tations for the hand-held devices IndraControl VEH 30.1 (DOK-
SUPPL*-VEH*30.1***-PR02-EN-P), IndraControl VEH 30.2 (DOK-
SUPPL*-VEH*30.2***-PR01-EN-P) or IndraControl VCH 08.1
(DOK-SUPPL*-VCH*08.1***-PR01-EN-P).
A further module slot for flexible extension is available on the VAM 41.1. On
delivery, this module slot is equipped with a blind plate.
Bosch Rexroth AG
IndraControl
VEH
or
IndraControl
VCH
Shutdown of the plant due to connecting an In‐
draControl VEH 30.1/30.2 or VCH 08.1 with
pressed STOP button.
45/83
Module Design
30.2
(DOK-SUPPL*-
08.1
(DOK-SUPPL*-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indracontrol vam 41.1

Table of Contents