X1: DC 24 V Voltage Supply VAC 30.2

Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
DANGER
For safety reasons, the voltage supply for the connection module (X1.1 pin1,
X1.2 pin1) must be monitored. If the voltage fails, the STOP button at the device
is inoperative.
NOTICE
Use only copper wire for wiring the connection terminals. Tighten the screws of
the screw terminals with a torque of 2.20 lb in (0.22 Nm).
All internally required voltages are generated with electrical isolation via a DC/
DC converter. The connection is designed as male connector strip S, 3.50 mm
pin spacing, so that cables up to a maximum line cross-section of 1.5 mm
be connected.
Parameter
Rated voltage U
N
Residual ripple at U
N
Emitted interference and surge immunity
Current consumption for U
N
Prescribed external protection
Reverse voltage protection
Fig.7-21:
Technical data of the DC 24 V connection VAC 30.2
NOTICE
The external voltage supply must have a rated voltage of 24 V and must not
exceed an output voltage of 30 V. The 24 V line to the connection module is to
be protected by a 2 A time-lag fusible cut-out.
DANGER
⇒ The DC 24 V input voltage must comply with the requirements of the "Pro‐
tective separation"!
⇒ Plug and unplug the connector only if there is no voltage!
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Risk of injury caused by voltage loss and non-
functioning STOP button!
Destruction of screw terminals, insufficient
contact and loss of UL certificiation if no copper
wire is used and/or wrong tightening torque.
Value
DC 24 V ; (+19 V to +30 V)
See figure below
U
= 35 V (for t < 100 ms)
max
0.7 A max.
Fusible cut-out, 2 A time-lag
Occurs via decoupling diode; the line-side
fuse is activated when polarity reversal oc‐
curs.
Possible damages due to missing protection of
the 24 V lead.
Danger without protective separation!