Personality Function - Bosch Rexroth IndraControl VAM 11.1 Project Planning Manual

Table of Contents

Advertisement

62/83
Bosch Rexroth AG
Interfaces
7.8.7

Personality Function

Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
RJ45, female connector, 8-pin
Cable type:
Transmission rate:
Fig.7-27:
Ethernet interface
Fig.7-28:
Pin assignment of the Ethernet interface VAC 30.2 X3
The configuration of the Ethernet interface is described in the doc‐
umentations of the hand-held terminals IndraControl VEH30.1
(DOK-SUPPL*-VEH*30.1***-PR02-EN-P), IndraControl VEH 30.2
(DOK-SUPPL*-VEH*30.2***-PR01-EN-P)
VCH 08.1 (DOK-SUPPL*-VCH*08.1***-PR01-EN-P).
In the majority of cases, the plant features a continuous Ethernet network.
However, M-keys, STOP buttons or enabling buttons are firmly assigned to one
control. The STOP button and the enabling button are hard-wired to the VAC
30.2 connection module (corresponds to the VAM 11.1 and VAM 41.1 connec‐
tion modules). The network data of the IndraControl VEH 30.1/30.2 or VCH 08.1
as well as the IP address of the control are saved in the VAC 30.2 connection
module via the memory function.
Thus, different sections of a plant can be visualized by means of one Indra‐
Control VEH 30.1 or VCH 08.1 via several IndraControl VAC 30.2 connection
modules. With each change of the plug-in location, the IndraCon‐
trol VEH 30.1/30.2 or the VCH 08.1 gets e. g. a new target IP address or UDP
address.
The IndraControl VEH 30.1/30.2 or VCH 08.1 applies the network settings that
are read out from the VAC 30.2 connection module after every restart. These
settings can be adjusted in the "Rexroth settings" of the VEH 30.1/30.2 or VCH
08.1 IndraControl hand-held terminals. These settings are saved in the Indra‐
Control VAC 30.2.
The configuration of the Ethernet interface is described in the doc‐
umentations of the hand-held terminals IndraControl VEH30.1
(DOK-SUPPL*-VEH*30.1***-PR02-EN-P), IndraControl VEH 30.2
(DOK-SUPPL*-VEH*30.2***-PR01-EN-P)
VCH 08.1 (DOK-SUPPL*-VCH*08.1***-PR01-EN-P).
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Shielded, twisted pair
10 or 100 Mbits/s; class D
or
or
IndraControl
IndraControl